API RP 2030-2005
Application of Fixed Water Spray Systems for Fire Protection in the Petroleum and Petrochemical Industries (THIRD EDITION)

Standard No.
API RP 2030-2005
Release Date
2005
Published By
API - American Petroleum Institute
Status
Replace By
API RP 2030:2014
API RP 2030-2014
Latest
API RP 2030:2014
API RP 2030-2014
Replace
API PUBL 2030:1998
Scope
When addressing loss prevention an organization should consider the use of fixed fire protection systems@ one of which is water spray systems. Water spray systems appear similar to sprinkler systems in some respects; however@ the intended uses@ applicable Fire Codes and design criteria differ. This publication provides guidance for the petroleum industry and some petrochemical industry applications (for non-water-reactive petrochemicals with physical and combustion characteristics comparable to hydrocarbons) in determining where water spray systems might be used to provide protection from fire damage for equipment and structures. Damage to process equipment and structural steel also can be limited by fireproofing@ applying water through manual hose streams or applying water from fixed or mobile monitor nozzles. These methods are covered in API RP 2218 Fireproofing Practices in Petroleum and Petrochemical Processing Plants@ API RP 2001 Fire Protection in Refineries and other referenced documents such as the NFPA Fire Protection Handbook. The specifics of water spray system design@ installation and component types are covered in the publications referenced in Section 2@ principally NFPA 15@ and are not duplicated in this publication. The following other special applications of water spray are outside the scope of this publication; ? Foam sprinkler systems used to supplement water spray systems and extinguish flammable liquid fires (see NFPA 16 for details). ? Vapor mitigation systems which have been used successfully by several major corporations to reduce the potential effects of releases of hazardous materials such as HF acid (see API RP 751 for additional information). ? Water curtains used in special situations to minimize radiant heat or disperse hydrocarbon vapors before ignition. ? Traditional applications of sprinklers in non-process buildings ? Water mist systems as described in NFPA 750

API RP 2030-2005 history

  • 0000 API RP 2030:2014
  • 2005 API RP 2030-2005 Application of Fixed Water Spray Systems for Fire Protection in the Petroleum and Petrochemical Industries (THIRD EDITION)
  • 0000 API PUBL 2030:1998



Copyright ©2024 All Rights Reserved