"These requirements cover Type MC-HL metal-clad cable for use in hazardous (classified) locations@ Class I@ Division 1@ Groups A@ B@ C@ and D; Class II@ Division 1@ Groups E@ F@ and G; Class I@ Zone 1@ Groups IIA@ IIB@ and IIC in accordance with the National Electrical Code@ NFPA 70. These requirements cover Type ITC-HL instrumentation tray cable for use in hazardous (classified) locations@ Class I@ Division 1@ Groups A@ B@ C@ and D@ and Class I@ Zone 1@ Groups IIA@ IIB@ and IIC in accordance with the National Electrical Code@ NFPA 70. These requirements cover explosion-proof and dust ignition-proof cable sealing fittings for use in hazardous (classified) locations@ Class I@ Division 1 and 2@ Groups A@ B@ C@ and D; Class II@ Division 1 and 2@ Groups E@ F@ and G; in accordance with the National Electrical Code@ NFPA 70. These requirements cover explosion-proof and dust ignition-proof cable sealing fittings intended for use on mobile offshore oil rigs and drilling platforms@ and other marine vessels. Investigations of these fittings include an evaluation for conformity to the installation and use provisions of Title 46 Code of Federal Regulations Sub-part 111.105 and Subpart 111.60 of the United States Coast Guard Electrical Engineering Regulations@ Subchapter J (Parts 110 to 113 inclusive) as applied by the authority having jurisdiction. These requirements cover increased safety ?e? cable fittings and flameproof ?d? cable sealing fittings for use in Class I@ Zone 1 Groups IIA@ IIB and IIC hazardous (classified) locations@ in accordance with the National Electrical Code@ NFPA 70. These requirements cover increased safety ?e? cable fittings and flameproof ?d? cable sealing fittings for use in hazardous (classified) locations@ Class I@ Zone 1 for use on mobile offshore oil rigs and drilling platforms@ and other marine vessels. Investigations of these fittings include an evaluation for conformity to the installation and use provisions of Title 46 Code of Federal Regulations Sub-part 111.105 and Subpart 111.60 of the United States Coast Guard Electrical Engineering Regulations@ Subchapter J (Parts 110 to 113 inclusive) as applied by the authority having jurisdiction. These requirements cover increased safety ""e"" cord termination fittings and flameproof ""d"" cord termination fittings for use only with UL Listed extra-hard usage cord in hazardous (classified) locations@ Class I@ Zone 1 in accordance with the National Electrical Code@ NFPA 70. These requirements cover dust ignition protection by enclosure ?t? and ?tD? cable fittings for use in Zone 20@ 21@ and 22 hazardous (classified) locations in accordance with the National Electrical Code@ NFPA 70. These requirements cover dust ignition protection by enclosure ?t? and ?tD? extra-hard usage cord connectors for use in Zone 20@ 21@ and 22 in accordance with the National Electrical Code@ NFPA 70. These requirements apply to cables and cable fittings for hazardous locations under the following atmospheric conditions: a) A minimum ambient temperature of minus 50??(minus 58??; b) An oxygen concentration of not greater than 21 percent by volume; and c) A nominal barometric pressure of one atmosphere."
UL 2225-2011 history
1970UL 2225-2022 UL Standard for Safety Cables and Cable-Fittings For Use In Hazardous (Classified) Locations
2019UL 2225 BULLETIN-2019 UL Standard for Safety Cables and Cable-Fittings For Use In Hazardous (Classified) Locations (COMMENTS DUE: APRIL 22@ 2019)
2018UL 2225 CRD-2018 UL Standard for Safety Cables and Cable-Fittings For Use In Hazardous (Classified) Locations - Section / Paragraph Reference: 19 Subject: Non-drying thickened mineral oil-based thread sealant (Edition 4: September 30@ 2013)
2018UL 2225 BULLETIN-2018 UL Standard for Safety Cables and Cable-Fittings For Use In Hazardous (Classified) Locations (COMMENTS DUE: APRIL 30@ 2018)
2017UL 2225 BULLETIN-2017 UL Standard for Safety Cables and Cable-Fittings For Use In Hazardous (Classified) Locations (COMMENTS DUE: FEBRUARY 27@ 2017)
2016UL 2225 BULLETIN-2016 UL Standard for Safety Cables and Cable-Fittings For Use In Hazardous (Classified) Locations (COMMENTS DUE: DECEMBER 26@ 2016)
2015UL 2225 CRD-2015 UL Standard for Safety Cables and Cable-Fittings For Use In Hazardous (Classified) Locations - Section / Paragraph Reference: Section 37 Subject: Div. 2 Marking (Edition 4: September 30@ 2013)
2015UL 2225 BULLETIN-2015 UL Standard for Safety Cables and Cable-Fittings For Use In Hazardous (Classified) Locations (COMMENTS DUE: NOVEMBER 2@ 2015)
2013UL 2225 BULLETIN-2013 UL Standard for Safety Cables and Cable-Fittings For Use In Hazardous (Classified) Locations (COMMENTS DUE: JULY 29@ 2013)
2013UL 2225-2013 UL Standard for Safety Cables and Cable-Fittings For Use In Hazardous (Classified) Locations (Fourth Edition)
2011UL 2225-2011 UL Standard for Safety Cables and Cable-Fittings For Use In Hazardous (Classified) Locations (Third Edition)
2010UL 2225 BULLETIN-2010 UL Standard for Safety Cables and Cable-Fittings For Use In Hazardous (Classified) Locations (COMMENTS DUE: May 03@ 2010)
2005UL 2225 BULLETIN-2005 UL Standard for Safety Cables and Cable-Fittings For Use In Hazardous (Classified) Locations
2005UL 2225-2005 UL Standard for Safety Cables and Cable-Fittings For Use In Hazardous (Classified) Locations (Second Edition)
2004UL 2225 BULLETIN-2004 UL Standard for Safety Cables and Cable-Fittings For Use In Hazardous (Classified) Locations
2003UL 2225 BULLETIN-2003 UL Standard for Safety Cables and Cable-Fittings For Use In Hazardous (Classified) Locations
1996UL 2225-1996 UL Standard for Safety Metal-Clad Cables and Cable-Sealing Fittings for Use in Hazardous (Classified) Locations (First Edition; Reprint with Revisions Through and Including July 21@ 2004)