This standard specifies the ascorbic acid reduction-molybdenum blue spectrophotometric method for the determination of phosphorus pentoxide in ambient air. This standard applies to the determination of phosphorus pentoxide in ambient air. When the ambient air collected is 5.0 m (standard state) and the sample volume is adjusted to 50.0 ml, the detection limit of the method is 0.20 μg/m, and the lower limit of determination is 0.80 μg/m.
HJ 546-2015 Referenced Document
HJ/T 194 Manual methods for ambient air quality monitoring
HJ/T 374 Technical requirement and test procedures for total suspended particulates sampler
HJ 546-2015 history
2015HJ 546-2015 Ambient air-Determination of phosphorus pentoxide Molybdenum blue spectrophotometric method
2009HJ 546-2009 Ambient air.Determination of phosphorus pentoxide.Molybdenum blue ascorbiaccid to deoxidize spectrophotometric method