This document gives the terms and definitions, method principles, reagents and materials, instruments and equipment, samples, analysis steps, result calculation, quality assurance and quality control, etc. for the determination of Sr2+ and Ba2+ in water by ion chromatography. This document is applicable to the determination of Sr2+ and Ba2+ in surface water, groundwater, and industrial wastewater. When the injection volume is 20 μL, the Sr2+ determination range is 0.5 mg/L ~ 100 mg/L, the detection limit is 0.125 mg/L, and the lower determination limit is 0.50 mg/L; the Ba2+ determination range is 1.0 mg/L ~ 100 mg/L, and the detection limit is 0.250 mg/L, the lower limit of determination is 1.00mg/L.
T/SXQCA 001-2023 history
2023T/SXQCA 001-2023 Water quality-Determination of water soluble cations(Sr2+、Ba2+) -Ion chromatography
2022T/SXQCA 001-2022 Technical specification for protective equipment and installation quality inspection of civil air defense engineering of urban rail transit
2021T/SXQCA 001-2021 On-site disposal of radiation accidents- Technical specification for radioactive source collection and storage