1 Scope
This document is applicable to mechanical by wood pellets fed roomheaters, inset appliances
and cookers up to 50 kW nominal heat output.
The intended use of the appliances is space heating in residential buildings and can
be cooking. They can be fitted with a boiler (integral part of the appliance containing
water to be heated up) for the supply of hot water for central heating systems.
These appliances typically use auxiliary energy which is measured in this document
as well. They can be operated with either natural draught or fan-assisted combustion
air.
NOTE A fan-assisted appliance does still operate under negative pressure in the flue gas
system.
These appliances burn wood pellets only as specified. They only operate with the firedoors
closed.
This document is not applicable to appliances:
— with boiler intended for water systems having water temperatures above 110 °C and
3 bar;
— with boiler intended for water systems having direct contact with sanitary hot water;
— intended to be used with a pure horizontal exhaust (through the building wall);
— with flue gas condensation in the appliance;
BS EN 16510-2-6:2022 Referenced Document
EN 15456:2008 Heating boilers - Electrical power consumption for heat generators - System boundaries - Measurements
EN 16510-1:2022 Residential solid fuel burning appliances - Part 1: General requirements and test methods
EN 16510-2-2:2022 Residential solid fuel burning appliances - Part 2-2: Inset appliances including open fires
EN 16510-2-3:2022 Residential solid fuel burning appliances - Part 2-3: Cookers
BS EN 16510-2-6:2022 history
2023BS EN 16510-2-6:2022 Residential solid fuel burning appliances - Mechanically by wood pellets fed roomheaters, inset appliances and cookers