UL 2250-2017
UL Standard for Safety Instrumentation Tray Cable (Third Edition)

Standard No.
UL 2250-2017
Release Date
2017
Published By
Underwriters Laboratories (UL)
Status
Replace By
UL 2250-2022
Latest
UL 2250-2022
Scope
These requirements cover Type ITC instrumentation control cables consisting of two or more current-carrying copper or thermocouple alloy conductors with or without either or both: a) Grounding conductor(s)@ bare or insulated@ and b) One or more optical-fiber members@ all under an overall jacket. These electrical and composite electrical/optical-fiber cables are intended for use (optical and electrical functions associated in the case of a hybrid cable) on circuits rated 150 V or less and 5 A or less in accordance with Article 727 and other applicable parts of the National Electrical Code (NEC). These cables are rated 300 V but are not so marked. Cables for direct-burial are so marked. Jacketed Type ITC cables comply with one of the following 70@000 Btu/h (20.5 kW) vertical-tray flame tests: a) The UL test referenced in 35.2.1 ?C 35.2.2 of these requirements. These paragraphs apply the test method described as the UL Flame Exposure (smoke measurements are not applicable) in the Standard for Vertical-Tray Fire-Propagation and Smoke-Release Test for Electrical and Optical-Fiber Cables@ UL 1685. b) The FT4/IEEE 1202 test referenced in 35.3.1 of these requirements. This paragraph applies the test method described as the FT4/IEEE 1202 Type of Flame Exposure (smoke measurements are not applicable) in UL 1685. c) For limited-smoke cable@ either the UL test or the FT4/IEEE 1202 test referenced in 35.4.1 and 35.4.2 of these requirements. These paragraphs apply the test methods described in UL 1685 with smoke measurements included. A cable that contains one or more electromagnetic shields may be surface marked or have a marker tape to indicate that it is ??ielded??A cable that contains one or more optical-fiber members has ??F??upplementing the type letters and is limited (see 14.3) to carrying optical energy that has been ruled not hazardous to the human body. All Type ITC cables qualify for exposure to sunlight (a 720-hour sunlight-resistance test is required ?C see 29.1). A marking is not required; however@ where used@ the marking consists of ??n res??r ??nlight resistant??n the tag and either on the overall cable jacket or legible through the jacket [see 42.1(i)]. These cables may have a metal sheath or armor over the required non/metallic jacket. These requirements do not cover the optical or other performance of any optical-fiber member or group of such members. The overall jacket on Type ITC cable is a ??s/vapor-tight continuous sheath??n the sense discussed in Sections 501.5 (D) and 501.5 (E) of the National Electrical Code@ ANSI/NFPA 70@ (see 16.1.1). Cables that are surface marked ??R??re for use as exposed runs of not more than 50 ft (15.2 m) between a cable tray and equipment where the cables are supported and secured every 6 ft (1.8 m).

UL 2250-2017 history

  • 1970 UL 2250-2022 Instrumentation tray cable
  • 2017 UL 2250-2017 UL Standard for Safety Instrumentation Tray Cable (Third Edition)
  • 2016 UL 2250 BULLETIN-2016 UL Standard for Safety Instrumentation Tray Cable (COMMENTS DUE: DECEMBER 5@ 2014)
  • 2015 UL 2250 CRD-2015 UL Standard for Safety Instrumentation Tray Cable - Section / Paragraph Reference: 17.1.1@ 17.3.1 and 17.3.3 Subject: Addition of Stainless Steel as a Welded and Corrugated Metal Sheath (Edition 2: April 3@ 2006)
  • 2014 UL 2250 BULLETIN-2014 UL Standard for Safety Instrumentation Tray Cable (COMMENTS DUE: October 27@ 2014)
  • 2013 UL 2250 BULLETIN-2013 UL Standard for Safety Instrumentation Tray Cable (COMMENTS DUE: February 4@ 2013)
  • 2009 UL 2250 BULLETIN-2009 UL Standard for Safety Instrumentation Tray Cable (COMMENTS DUE: September 14@ 2009)
  • 2008 UL 2250 BULLETIN-2008 UL Standard for Safety Instrumentation Tray Cable (COMMENTS DUE: NOVEMBER 19@ 2008)
  • 2006 UL 2250-2006 UL Standard for Safety Instrumentation Tray Cable Second Edition
  • 2005 UL 2250 BULLETIN-2005 UL Standard for Safety Instrumentation Tray Cable
  • 2004 UL 2250 BULLETIN-2004 UL Standard for Safety Instrumentation Tray Cable
  • 2003 UL 2250 BULLETINS-2003 (Draft)5/30/2003 (60p)
  • 2003 UL 2250 BULLETIN-2003 UL Standard for Safety Instrumentation Tray Cable
  • 2000 UL 2250 BULLETINS-2000 UL Standard for Safety Instrumentation Tray Cable (08/16/2000 (2p)@ 02/25/2000 (22p))
  • 1999 UL 2250-1999 Instrumentation tray cable
  • 1996 UL 2250-1996 UL Standard for Safety Instrumentation Tray Cable (First Edition; Reprint with Revisions Through and Including September 28@ 2004)