1.1 This test method covers the quantitative determination of oxygenates: methyl-t-butylether (MTBE), di-
1.2 This test method covers the following concentration ranges: 0.1-20 volume % per component for ethers and alcohols; 0.1-2 volume% benzene; 1-15 volume % for toluene, 10-40 volume % total (C
1.3 The method has not been tested by ASTM for refinery individual hydrocarbon process streams, such as reformates, fluid catalytic cracking naphthas, etc., used in blending of gasolines.
1.4 SI units of measurement are preferred and used throughout this test method.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.