VDI 2081 BLATT 1-2019
Air-conditioning - Noise generation and noise reduction

Standard No.
VDI 2081 BLATT 1-2019
Release Date
2019
Published By
VDI - Verein Deutscher Ingenieure
Status
Replace By
VDI 2081 Blatt 1-2022
Latest
VDI 2081 Blatt 1-2022
Scope
Diese Richtlinie gilt f??r alle RLT-Anlagen@ die der L??ftung oder Klimatisierung von Aufenthalts- und Arbeitsr?umen dienen. Sie bezieht sich auf die im Zusammenhang mit der Errichtung solcher Anlagen zu stellenden schallschutztechnischen Anforderungen und die daf??r zu treffenden Ma?nahmen. Sie bezieht sich nicht auf Ma?nahmen an der Baukonstruktion@ in denen die RLT-Anlagen installiert sind. measures for noise reduction are stipulated. Such measures are proposed in this standard. The ventilation and air-conditioning system installed in accordance with the acknowledged rules of technology contributes by itself to noise reduction@ but this noise reduction normally has to be enhanced by secondary measures (silencers or sound insulation jacket). Noise reduction in the room requiring noise protection or the acoustic properties of the room are determined by the construction of the room in combination with the installed ventilation and air-conditioning system. Noise control measures shall be considered as early as the building is planned@ given that retrofitting is hardly practicable or can only be achieved through considerable effort. Rooms requiring noise protection shall not be directly adjacent to central ventilation equipment rooms. Structural noise control shall be given particular consideration. This standard describes the noise sources and the noise reduction in ventilation and air-conditioning systems in order to give guidance in acoustic planning and design. Additionally@ an approximation method shows how to determine the sound pressure level generated by the ventilation and airconditioning system in the room requiring noise protection. The calculation of the acoustic properties of buildings complies with DIN EN 12354-5 and describes calculation models for the sound pressure levels generated by building services systems. The calculation is based mainly on measured data characterising both the noise sources and the building structures. Noise is transmitted from the ventilation system to the building through air and through structures. Transmission through the air duct is also relevant for the indirect noise transmission between rooms. Examples of application of the standard are described in VDI 2081 Part 2.

VDI 2081 BLATT 1-2019 history

Air-conditioning - Noise generation and noise reduction



Copyright ©2024 All Rights Reserved