Heating a test portion in a combustion tube at 250 0C, later at 500 0C. Passing through the liberated water carried by a flow of nitrogen into a tared absorption vessel filled with magnesium perchlorate. Weighing the absorption vessel and determination of the mass of water by difference.
ISO 3120:1976 history
2010ISO 3120:2010 diSodium tetraborates and crude sodium borates for industrial use; Determination of water content; Gravimetric method
1976ISO 3120:1976 diSodium tetraborates and crude sodium borates for industrial use; Determination of water content; Gravimetric method