1 Scope
EN 13611:2019, Clause 1 applies with the following modification and addition:
Modification:
The 1 st paragraph of EN 13611:2019, Clause 1 is replaced by:
This document specifies the safety, design, construction, and performance requirements
and testing for manually operated taps and presetting taps for burners and appliances
burning one or more gaseous fuels, hereafter referred to as “taps”.
This document is applicable to taps with declared maximum inlet pressures up to and
including 50 kPa and of nominal connection sizes up to and including DN 50 for use
with one or more fuel gases.
Addition:
This document is not applicable to:
a) manual operated shut-off valves conforming to EN 331:2015;
b) controls which use auxiliary energy (e.g. electrical energy supplied externally).
The 4 th paragraph of EN 13611:2019, Clause 1 is removed.
BS EN 1106:2022 Referenced Document
EN 14543:2017 Specification for dedicated liquefied petroleum gas appliances - Parasol patio heaters - Flueless radiant heaters for outdoor or amply ventilated area use
EN 30-1-1:2021 Domestic Cooking Appliances Burning Gas Fuel - Part 1-1: Safety - General
EN 331:2015 Manually operated ball valves and closed bottom taper plug valves for gas installations for buildings