T/ZZB 1214-2019
Electromagnetic type residual current operated cicuit-breaker with integral overcurrent protection(RCBO) (English Version)

Standard No.
T/ZZB 1214-2019
Language
Chinese, Available in English version
Release Date
2019
Published By
Group Standards of the People's Republic of China
Latest
T/ZZB 1214-2019
Scope
This standard specifies the terms and definitions, classification, basic requirements, RCBO characteristics, markings and other product information, standard working conditions for use and installation, and structure of electromagnetic residual current-operated circuit breakers with overcurrent protection (hereinafter referred to as RCBO). and operational requirements, testing, packaging, transportation and storage, and quality commitments. The RCBO specified in this standard is suitable for AC rated frequency 50 Hz, 60 Hz or 50/60 Hz, rated voltage not exceeding 440 V, rated current not exceeding 125 A, rated short-circuit capacity not exceeding 25 000 A, and the operating function has nothing to do with the power supply voltage Electromagnetic residual current operated circuit breakers with overcurrent protection for household and similar purposes. The RCBO specified in this standard is used to protect people from indirect contact. In this case, the exposed conductive parts of the equipment should be connected to a suitable ground electrode; it can also be used to protect buildings and similar line equipment from overcurrent. Provides protection against fire hazards caused by ground fault currents that persist due to failure of the overcurrent protective device to operate. The RCBO specified in this standard is suitable for use by non-professionals and does not require maintenance. The RCBO specified in this standard is intended for use in a pollution level 2 environment. The RCBO specified in this standard is suitable for isolation and suitable for use in IT systems. The RCBOs specified in this standard are of the enclosed type (a suitable enclosure is not required). The I2t characteristics of RCBO specified in this standard meet the requirements of energy level 3. This standard does not apply to:  ——RCBO used for motor protection;  ——RCBO whose setting current value can be adjusted by the user during use. Battery-based RCBOs are not included in the scope of this standard.

T/ZZB 1214-2019 history

  • 2019 T/ZZB 1214-2019 Electromagnetic type residual current operated cicuit-breaker with integral overcurrent protection(RCBO)
Electromagnetic type residual current operated cicuit-breaker with integral overcurrent protection(RCBO)



Copyright ©2024 All Rights Reserved