ASTM E671-98(2016)
Standard Specification for Maximum Permissible Thermal Residual Stress in Annealed Glass Laboratory Apparatus

Standard No.
ASTM E671-98(2016)
Release Date
2016
Published By
American Society for Testing and Materials (ASTM)
Status
Replace By
ASTM E671-98(2022)
Latest
ASTM E671-98(2022)
Scope
1.1 This specification covers a limit for thermal residual stress in reusable annealed glass laboratory apparatus as determined by prescribed photoelastic measurement procedures. 1.2 In broad classification, the laboratory glassware items covered by this specification, but not limited to, are: beakers Imhoff cones bottles, aspirator impingers bottles, dropping jars, battery bottles, gas washing jars, bell bottles, infusion jars, chromatography bottles, milk test jars, cylindrical bottles, reagent joints, ball and socket or standard taper bottles, weighing manometers bulbs, absorption percolators bulbs, leveling pycnometers bulbs, sampling stopcocks burets tubes, centrifuge condensers tubes, chromatography crystallizing dishes tubes, color comparison (turbidity) culture dishes tubes, combustion (ignition) custom apparatus tubes, connecting and adapter cylinders, graduated tubes, digestion and plain tubes, drying desiccators tubes, fermentation extraction tubes tubes, thistle (spray traps) flasks vapor traps fritted ware viscometers funnels watch glasses generators, Kipp grinder, tissue 1.3 This specification recognizes that photoelastic measurements are proportional to the difference of the principal stresses. The limit imposed represents a safety factor to cover a situation in which one of the principal stresses may be larger than the apparent stress. 1.4 This specification applies only to annealed glassware that is intended for sale as such. It excludes glassware that has been thermally tempered, ion-exchanged, or laminated with glass layers of differing expansion. The intent of this specification is to limit the residual stresses for safe consumer use in annealed glass, as it leaves the manufacturer. 1.5 Stresses introduced by thermal expansion differences within the glassware are covered by this specification. Graded and glass-to-metal seals are excluded.

ASTM E671-98(2016) Referenced Document

  • ASTM E1157 Standard Specification for Sampling and Testing of Reusable Laboratory Glassware
  • ASTM E1273 Standard Specification for Color Coding of Reusable Laboratory Pipets*2019-07-01 Update
  • ASTM F218 Standard Test Method for Analyzing Stress in Glass

ASTM E671-98(2016) history

  • 2022 ASTM E671-98(2022) Standard Specification for Maximum Permissible Thermal Residual Stress in Annealed Glass Laboratory Apparatus
  • 2016 ASTM E671-98(2016) Standard Specification for Maximum Permissible Thermal Residual Stress in Annealed Glass Laboratory Apparatus
  • 1998 ASTM E671-98(2010) Standard Specification for Maximum Permissible Thermal Residual Stress in Annealed Glass Laboratory Apparatus
  • 1998 ASTM E671-98(2004) Standard Specification for Maximum Permissible Thermal Residual Stress in Annealed Glass Laboratory Apparatus
  • 1998 ASTM E671-98 Standard Specification for Maximum Permissible Thermal Residual Stress in Annealed Glass Laboratory Apparatus
Standard Specification for Maximum Permissible Thermal Residual Stress in Annealed Glass Laboratory Apparatus



Copyright ©2024 All Rights Reserved