This standard specifies the method for the determination of manganese by flame atomic absorption spectrometry. This standard applies to the determination of manganese in groundwater. The measurement range is 0.01~1.5mg/L. Common components in groundwater do not interfere with the determination.
DZ/T 0064.32-1993 history
1970DZ/T 0064.32-2021 Methods of analysis of groundwater quality - Part 32: Determination of manganese content by flame atomic absorption spectrophotometry
1993DZ/T 0064.32-1993 Groundwater Quality Examination Method Determination of Manganese by Flame Atomic Absorption Spectrometry