This standard specifies the ion selective electrode method for the determination of water-soluble fluoride and total fluoride in soil. This standard is applicable to the determination of water-soluble fluoride and total fluoride in soil. When the sample volume is 5.0g and the sample pipetting volume is 40.0ml, the detection limit of this standard method for determination of water-soluble fluoride is 0.7 mg/kg, the lower limit of determination is 2.8 mg/kg, and the upper limit of determination is 125mg/kg ; When the sample volume is 0.2 g and the sample pipetting volume is 20.0 ml, the detection limit of the method for determining total fluoride is 63 mg/kg, the lower limit of determination is 252 mg/kg, and the upper limit of determination is 1.25×104 mg/kg.
HJ 873-2017 Referenced Document
HJ 613 Soil.Determination of dry matter and water content.Gravimetric method
HJ/T 166 Technical specification for soil environmental monitoring
HJ 873-2017 history
2017HJ 873-2017 Soil-Determination of water soluble fluoride and total fluoride - Ion selective electrode method