The sample is digested with a mixed acid of concentrated nitric acid, concentrated sulfuric acid, and concentrated perchloric acid. After digestion, the content of each metal ion in the sample is measured using the working curve method on an inductively coupled plasma optical emission spectrometer (ICP-OES).
T/CGIA 012-2019 history
2019T/CGIA 012-2019 Determination of metallic elements in graphene materials — Inductively coupled plasma emission spectrometry