1.1 This practice describes continuous sample conditioning by hydrogen ion exchange and measurement by electrolytic conductivity. It is commonly known as cation conductivity measurement in the power industry although it is actually an indication of anion contamination in high purity water samples. Measurements are typically in a range less than 1 µS/cm.
1.2 The actual conductivity measurements are made using Test Method D5391.
1.3 This practice does not provide for separate determination of dissolved carbon dioxide. Refer to Test Method D4519.
1.4 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM D1193 Standard Specification for Reagent Water
ASTM D3370 Standard Practices for Sampling Water from Closed Conduits
ASTM D3864 Standard Guide for Continual On-Line Monitoring Systems for Water Analysis
ASTM D4519 Standard Test Method for On-Line Determination of Anions and Carbon Dioxide in High Purity Water by Cation Exchange and Degassed Cation Conductivity
ASTM D5391 Standard Test Method for Electrical Conductivity and Resistivity of a Flowing High Purity Water Sample
ASTM D5540 Standard Practice for Flow Control and Temperature Control for On-Line Water Sampling and Analysis
ASTM D6504-11(2016)e1 history
2016ASTM D6504-11(2016)e1 Standard Practice for On-Line Determination of Cation Conductivity in High Purity Water
2011ASTM D6504-11 Standard Practice for On-Line Determination of Cation Conductivity in High Purity Water
2007ASTM D6504-07 Standard Practice for On-Line Determination of Cation Conductivity in High Purity Water
2000ASTM D6504-00 Standard Practice for On-Line Determination of Cation Conductivity in High Purity Water