IEC 60947-2:2016
Low-voltage switchgear and controlgear - Part 2: Circuit-breakers

Standard No.
IEC 60947-2:2016
Release Date
2016
Published By
International Electrotechnical Commission (IEC)
Status
 2019-07
Replace By
IEC 60947-2:2016/COR1:2016
Latest
IEC 60947-2:2019/COR1:2019
Replace
IEC 121A/71/FDIS:2016 IEC 60947-2:2006 IEC 60947-2 AMD 1:2009 IEC 60947-2 AMD 2:2013 IEC 60947-2 Edition 4.1:2009 IEC 60947-2 Edition 4.2:2013
Scope
This part of IEC 60947 series applies to circuit-breakers@ the main contacts of which are intended to be connected to circuits@ the rated voltage of which does not exceed 1 000 V a.c. or 1 500 V d.c.; it also contains additional requirements for integrally fused circuit-breakers. Circuit-breakers rated above 1 000 V a.c. but not exceeding 1 500 V a.c. may also be tested to this standard. It applies whatever the rated currents@ the method of construction or the proposed applications of the circuit-breakers may be. The requirements for circuit-breakers which are also intended to provide earth leakage protection are contained in Annex B. The additional requirements for circuit-breakers with electronic over-current protection are contained in Annex F. The additional requirements for circuit-breakers for IT systems are contained in Annex H. The requirements and test methods for electromagnetic compatibility of circuit-breakers are contained in Annex J. The requirements for circuit-breakers not fulfilling the requirements for over-current protection are contained in Annex L. The requirements for modular residual current devices (without integral current breaking device) are contained in Annex M. The requirements and test methods for electromagnetic compatibility of circuit-breaker auxiliaries are contained in Annex N. The requirements and test methods for d.c. circuit-breakers for use in photovoltaic (PV) applications are contained in Annex P. The requirements and test methods for circuit-breakers incorporating residual current protection with automatic reclosing functions are contained in Annex R. Supplementary requirements for circuit-breakers used as direct-on-line starters are given in IEC 60947-4-1@ applicable to low-voltage contactors and starters. The requirements for circuit-breakers for the protection of wiring installations in buildings and similar applications@ and designed for use by uninstructed persons@ are contained in IEC 60898. The requirements for circuit-breakers for equipment (for example electrical appliances) are contained in IEC 60934. For certain specific applications (for example traction@ rolling mills@ marine service) particular or additional requirements may be necessary. NOTE Circuit-breakers which are dealt with in this standard can be provided with devices for automatic opening under predetermined conditions other than those of over-current and undervoltage as@ for example@ reversal of power or current. This standard does not deal with the verification of operation under such pre-determined conditions. The object of this standard is to state: a) the characteristics of circuit-breakers; b) the conditions with which circuit-breakers shall comply with reference to: 1) operation and behaviour in normal service; 2) operation and behaviour in case of overload and operation and behaviour in case of short-circuit@ including co-ordination in service (selectivity and back-up protection); 3) dielectric properties; c) tests intended for confirming that these conditions have been met and the methods to be adopted for these tests; d) information to be marked on or given with the apparatus.

IEC 60947-2:2016 Referenced Document

  • CISPR 11-2015 Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
  • CISPR 22-2008 Information technology equipment – Radio disturbance characteristics – Limits and methods of measurement
  • IEC 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
  • IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
  • IEC 60269-1:2006 Low-voltage fuses - Part 1: General requirements
  • IEC 60364-1:2005 Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, definitions
  • IEC 60364-4-41:2005 Low-voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock
  • IEC 60364-4-42:2010 Low-voltage electrical installations - Part 4-42: Protection for safety - Protection against thermal effects
  • IEC 60364-4-43:2008 Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent
  • IEC 60364-4-44:2007 Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances
  • IEC 60364-5-51:2005 Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules
  • IEC 60364-5-52:2009 Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems
  • IEC 60364-5-53:2001 Electrical installations of buildings - Part 5-53: Selection and erection of electrical equipment; Isolation, switching and control