EIA/ECA-364-29C-2006
TP-29C Contact Retention Test Procedure for Electrical Connectors

Standard No.
EIA/ECA-364-29C-2006
Release Date
2006
Published By
ECIA - Electronic Components Industry Association
Scope
This standard establishes a test method to impose axial forces on the connector contacts to determine the ability of the connector to withstand forces that tend to displace contacts from their proper location within the connector insert and resist contact pullout. These forces may be the result of: loads on wire connected to the contacts; ?? forces required to restrict contact push-through during assembly of removable type contacts into connector inserts; ?? forces produced by mating contacts during connector mating; ?? dynamic forces produced by vibration and shock during normal use of the connectors; ?? forces relating to bundling strains on the wire. Object The object of this test procedure is to detail a standard method to assess the ability of the contact retaining system to withstand the axial mechanical stresses likely to be encountered during normal usage.